The problem
Many teams still check board thermals with a spreadsheet of θJA values. That number comes from a standard JEDEC test board, not from your layout, so it can be badly off on a real product. The alternative is waiting days for a CFD specialist.
How it works
You describe the board (size, copper layers, components and their power, thermal vias, airflow) and get a layered 3D finite-volume model of the copper and dielectric, with each package as a JEDEC two-resistor model. Give it a few measured temperatures (a thermocouple, an IR spot, an on-die sensor) and Ensemble Kalman Inversion calibrates the real cooling and copper spreading of your board, then re-predicts every junction with an uncertainty band.